SILENT HUNTER 3 ERROR CODE 1275 HOW TO
SILENT HUNTER 3 ERROR CODE 1275 SERIES
To determine the cause of this message it is necessary to follow a series of steps:
If necessary, replace the defective pump relay or correct wiring issues. If a pump relay is being used, problems may be caused by: 1) incorrect wire size and run from the controller to the relay, 2) a defective relay, 3) poor wire connections for circuit. Conduct a resistance check on the circuit to verify the fault. If a master valve is being used, the problem may be a defective solenoid or faulty wiring. SOLUTION - A few steps are necessary to determine cause of P-ERR message. Common causes include a defective solenoid on the master valve, incompatible or defective pump relay, or wire run too long between the relay and controller. Please click on the link below to find an Authorized Hunter Distributor in your area.ĬAUSE - The “P ERR” message is displayed when the P/MV circuit is drawing too much current. If you need a new SmartPort ® or hand-held remote receiver, Hunter makes our products and replacement parts available through our network of authorized distributors. Check the maximum station count setting on your hand-held remote. If “Err” message occurs when device is plugged into the SmartPort ® the device may have the wrong station count set or the device may be defective and should be replaced. The SmartPort ® connector may be damaged. The white SmartPort ® wire must be attached on the terminal next to the blue wire on the REM terminal, then red above ground. Make sure that the SmartPort wiring is not bundled with the field wiring. If the “Err” message is displayed without a device attached, check that SmartPort ® wiring is correct. SOLUTION - A few steps are necessary to determine cause of “Err” message. Please click on the link below to find an Authorized Hunter Distributor in your area.ĬAUSE - Noise entering the controller through the “SmartPort” wiring or it is wired incorrectly. If you need a new solenoid, Hunter makes our products and replacement parts available through our Network of authorized distributors. If the wire connections are good, the error message may indicate a bad solenoid. If the wire connected to screw terminal #2 now turns on our original zone #1, it is further confirmation the problem is with the original #2 wire or connections. You can further confirm the problem is in the original #2 wire by now trying to run zone #2. If zone 1 now faults out, it is confirmed that there is a short in the wire from the controller to your zone valve, a short in the connections to the wire or at the valve solenoid itself. For example if zone #2 faults, disconnect the #2 wire from the controller and put it in the #1 screw terminal and put the #1 wire into the #2 screw terminal.
Disconnect the faulting wire from the controllers screw terminal and switch it with a wire that is working. SOLUTION - To determine the cause of this message it is necessary to follow a series of steps. Please click on the link below to find an Authorized Hunter Distributor in your area.ĬAUSE - The Station # ERR (for example 1 ERR) is a diagnostic message that appears when your controller is detecting a fault on that corresponding irrigation zone.
SOLUTION - To determine the cause of this message it is necessary to follow a series of steps. Station # ERR Message CAUSE - The Station # ERR (for example 1 ERR) is a diagnostic message that appears when your controller is detecting a fault on that corresponding irrigation zone. Greenhouse, Nursery, and Open-Field Irrigation.